NFPA life safety engineer Ron Coté settles the debate over second egress doors and exit signs.


By Peter Fabris, Contributing Editor | June 18, 2015
Two myths regarding NFPA 101 Life Safety Code debunked

Image: Pixabay

In Compliance column in the May/June issue of NFPA Journal, Ron Coté, Principal Life Safety Engineer at the National Fire Protection Agency, debunks two myths regarding NFPA 101, Life Safety Code.

The first myth is that all assembly occupancy rooms with an occupancy load more than 50 must have a second egress door. This is not true, although many do have second exit access doors “in order not to violate the common path of travel limitation,” Coté writes.

For most room locations and arrangements, a second exit access door from the room can be positioned to provide occupants with a second travel path. The presence of the second exit access door can reduce what would otherwise be an excessive common path of travel to one that is within the permitted distance.

Coté also debunks the myth that exit signs are required at exits only. The signs are actually required in three locations: at exits, in the exit access, and in exit access corridors of new construction. They are required in the exit access when the exit or way to reach the exit is not readily apparent, as might be the case where additional turns in the egress path are needed to reach an exit.

They may also be needed when in exit access corridors of new construction no point is in excess of the particular sign’s rated viewing distance or the 100-foot (30-meter) default value, whichever is less, from the nearest sign.

Related Stories

Codes and Standards | Sep 17, 2019

Zero energy buildings can be constructed with no added upfront cost

ROI can be realized in as little as one year.

Codes and Standards | Sep 13, 2019

Researchers use U. of Arkansas buildings as testbed for CLT panels

Investigation could influence future use of the materials.

Codes and Standards | Sep 13, 2019

At least 30 U.S. cities have adopted stricter building energy codes since 2017

Some followed their states in implementing more robust standards.

Codes and Standards | Sep 12, 2019

Illinois law sets maximum retainage on private projects

The change is expected to give contractors bigger checks earlier in project timeline.

Codes and Standards | Sep 10, 2019

Retreat may be the best option for some coastal communities in face of sea level rise

A new study makes the case for relocating in a "strategic, managed" manner.

Codes and Standards | Sep 9, 2019

Free app calculates maximum allowable heights and areas for buildings

A free app that calculates the maximum allowable heights and areas for buildings of various occupancy classifications and types of construction has been released.

Codes and Standards | Sep 6, 2019

Standard for assessing frame deflection using one component polyurethane foams updated

The standard offers guidance when installing fenestration products.

Codes and Standards | Aug 29, 2019

The high cost of gridlock: $166 billion per year

Growing economy means more jobs, more cars, more hours stuck in traffic.

Codes and Standards | Aug 29, 2019

Industry leaders ask for government help as trades shortage worsens

AGC asks for more funding for education and increased immigration to fill gaps.

Codes and Standards | Aug 29, 2019

Code-conforming wood design guide available

The guide summarizes provisions for the use of wood and wood products in the 2018 IBC.

boombox1
boombox2
native1

More In Category




halfpage1

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021