New rule mandates annual parapet inspections for New York City buildings

Codes and Standards

New rule mandates annual parapet inspections for New York City buildings

Beginning January 1, 2024, New York City building owners must undertake a yearly inspection of parapet walls, then remedy any hazardous conditions.


By Hoffmann Architects | September 13, 2023
New rule mandates annual parapet inspections for New York City buildings Hoffmann Architects
Photo: Hoffmann Architects

In November 2021, New York City enacted Local Law 126 of 2021, which is well-known in the building industry for establishing new requirements for periodic parking garage inspections. At the same time, the legislation added a section to the NYC Administrative Code mandating periodic observation of building parapets.

To allow owners time to prepare, the City set the start date for the new parapet observations for January 1, 2024.

What is required?

All buildings in New York City with parapets facing a street, sidewalk, or other public right-of-way must undergo a professional parapet observation every year.

Unlike the Facade Inspection Safety Program (FISP), which excludes buildings under six stories, the parapet rule applies to all buildings, regardless of height, with the exception of detached single- or two-family homes. While FISP inspections are conducted on a five-year cycle, and parking garage inspections are required at least every six years, the newly mandated parapet observation must be done annually.

The good news: owners do not need to file the observation report with the Department of Buildings (DOB). Whereas facade and garage inspection reports follow prescriptive formats and must be electronically submitted, parapet reports need only be kept on file by the building owner. Archives of at least six years of parapet reports must be made available should the DOB request them.

What happens if there is a hazardous condition?

Immediately upon observing an unsafe condition, the professional performing the observation is required to notify the DOB. The building owner must promptly install public protection, such as sidewalk sheds, fences, and/or safety netting, which must remain in place until the problem is remedied. Unsafe conditions must be corrected within 90 days.

What is included in the observation report?

In contrast to the FISP and parking garage laws, the new parapet rule is not prescriptive as to report sections and format. However, the report does need to include:

  • Basic building information, including address and owner contact details;
  • Name and contact details for the professional performing the observation;
  • Date of the observation;
  • Location plan and construction information for the parapets, including material, height, and thickness;
  • Description of general conditions;
  • Unsafe conditions and actions taken to remedy them;
  • Repairs since the previous report; and
  • Dated photos documenting conditions.

Rather than filing the report with the DOB, the owner retains parapet observation reports for at least six years and must be prepared to furnish them to the DOB upon request.

What steps should owners take now?

With the requirements set to begin on the first of the year, owners have just a few months to plan. If a mandated FISP inspection is scheduled for 2024, adding a separate parapet observation report to that program may be a cost-effective strategy. Similarly, parapet observation can be incorporated into other planned exterior work, such as roof rehabilitation or facade cleaning.

A design professional can offer guidance on the simplest and most budget-conscious way to meet the new annual parapet requirements as part of existing maintenance and repair programs.

Resources

RCNY §103-15: Periodic Observation of Building Parapets

Local Law 126 of 2021 – see §28-301.1.1, p. 168

“Design Guide for Parapets: Safety, Continuity, and the Building Code,” Hoffmann Architects + Engineers JOURNAL

Hoffmann Architects + Engineers specializes in the rehabilitation of building exteriors.

Our design professionals have worked with hundreds of New York City building owners to meet inspection and repair requirements since the first facade law in 1980. We provide up-to-date guidance to help owners comply with the code and safely maintain their properties. Reach us at 212-789-9915 or hoffarch.com/contact.

Related Stories

| Apr 10, 2013

DOD should continue LEED-Silver or equivalent rating standard, says NRC

The Department of Defense should continue to require that its new buildings or major renovations to facilities be designed to achieve a LEED-Silver or equivalent rating, says a new report from the National Research Council.

| Apr 10, 2013

EPA proposes emissions rules affecting light construction vehicles

The Environmental Protection Agency has proposed air-pollution standards that it says will reduce the amount of sulfur in U.S. gasoline by two-thirds and impose fleet-wide pollution limits on new vehicles.

| Apr 10, 2013

New skyscraper designs raising the bar on green standards

Though most new skyscraper designs have a traditional look, they are including a wider array of sustainable elements to use energy and water more efficiently and improve human health.

| Apr 5, 2013

Lack of national standards on design of bioterror labs creates higher risk for accidents, panel says

U.S. labs that conduct research on bioterror germs such as anthrax are at risk for accidents because they do not have uniform design and operation standards, according to a Congressional investigative group.

| Apr 5, 2013

Builders Hardware Manuf. Assn. revises three standards for hinges, locks, and latches

The Builders Hardware Manufacturers Association (BHMA) released three new revisions to the ANSI/BHMA standardsfor hinges, interconnected locks, and sliding and folding hardware.

| Apr 5, 2013

New items to ASHRAE/IES energy standard open for public comment

The 2013 version of the ANSI/ASHRAE/IES Standard 90.1-2010, Energy Standard for Buildings Except Low-Rise Residential Buildings, is scheduled for publication later this year, and 26 proposed addenda are open for public comment.

| Apr 5, 2013

No evidence that mandatory building energy labeling improves efficiency, study says

The Building Owners and Managers Association (BOMA) International and the Greater Boston Real Estate Board (GBREB) released a report, “An Economic Perspective on Building Labeling Policies,” that questions the efficacy of mandatory building energy labeling.

| Mar 27, 2013

Practical application of Legionella prevention standards the focus of ASHRAE project

An American Society of Heating, Refrigerating and Air-Conditioning Engineers committee drafting tough new standards to prevent the waterborne bacteria Legionella is focused on how to apply the standards in the real world.

| Mar 27, 2013

Open discussion of regulations on tap at AGC’s 2013 Federal Contractors Conference

The AGC Federal Contractors Conference provides a venue for contractors and federal agency personnel to meet in a collaborative forum to review federal construction contracting issues from around the United States.

| Mar 27, 2013

New BACnet standard offers significant improvements to alarm handling

Changes to the newly published BACnet standard from ASHRAE will encourage smart building automation controls systems including alarms.

boombox1
boombox2
native1

More In Category




halfpage1

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021