New guide for installation of mineral fiber pipe insulation on chilled water systems

Codes and Standards

New guide for installation of mineral fiber pipe insulation on chilled water systems

Developed for professional insulation contractors, the 36-page guide recommends methods for insulating chilled water piping systems using a vapor-sealed mineral fiber pipe insulation. 


By Peter Fabris, Contributing Editor | July 27, 2015
New guide for installation of mineral fiber pipe insulation on chilled water systems

Photo: Steve Jurvetson, Creative Commons

The North American Insulation Manufacturers Association (NAIMA) has issued a new publication, “Guide to Insulating Chilled Water Piping Systems With Mineral Fiber Pipe Insulation.” 

Developed for professional insulation contractors, the 36-page guide recommends methods for insulating chilled water piping systems using a vapor-sealed mineral fiber pipe insulation.

"Insulation systems are critical to limiting heat losses and preventing condensation on pipe surfaces operating from 33 degrees F to 60 degrees F (0.5 degrees C to 15.6 degrees C) within conditioned spaces in commercial and institutional buildings," says Charles Cottrell, vice president technical services for NAIMA. "When poorly applied, however, an insulation system can compromise insulation effectiveness.” 

“NAIMA developed this step-by-step guide for applying vapor-sealed mineral fiber pipe insulation, which when installed according to the guide's recommendations, can effectively control condensation, help extend the life of the insulation system, and save energy," Cottrell says.

The guide addresses the installation of standard ASJ jacketed pipe insulation and presents recommendations based on reliable engineering principles and research, as well as consultation with manufacturers, contractors, and industry experts.

It details insulation application on straight pipe; on pipe system fittings including flanges, couplings, elbows, tees, and valves; and on 45- and 90-degree elbows.  Also included are details on vapor dams, pipe supports, and field-applied jackets.

Other sections include performance criteria, a guide specification, and installation checklist. Click here to download a free copy of the guide.

Related Stories

Codes and Standards | Dec 8, 2021

Proposals to add more multifamily to Atlanta prompt drive for Buckhead to secede

City aims to increase housing as projections point to sharp population increase.

Codes and Standards | Dec 7, 2021

Design problems now the primary cause of construction claims and disputes

More likely to occur due to more tight timescales imposed upon third parties engaged in design.

Codes and Standards | Dec 5, 2021

New standard for Phase I environmental reports requires more research work on many sites

Update affects around 250,000 commercial real estate transactions a year.

Codes and Standards | Nov 30, 2021

Dept. of Energy publishes RFP for technical assistance on supporting better building codes

Addresses advanced standards to reduce energy consumption and GHG emissions.

Codes and Standards | Nov 29, 2021

FAA seeking design of air traffic control towers of the future

Call for design submissions for safe, efficient structures.

Codes and Standards | Nov 28, 2021

Efficient electric water heaters in multifamily buildings significantly reduce carbon emissions

In buildings with 5+ units, water heating uses more energy than space heating, cooling, or lighting.

Codes and Standards | Nov 23, 2021

New York’s Labor Law Section 240 and how it affects general contractors

The ‘Scaffold Law’ was first enacted by the New York State Legislature in 1885 and is one of the single most-used laws in construction accident cases.

Codes and Standards | Nov 22, 2021

ABC’s Construction Technology Report finds focus on solving operational problems

More than half rely on project management software.

Codes and Standards | Nov 22, 2021

Contractors say 811 utility location system has significant flaws

More than half of firms in survey report damages, near misses because lines were unmarked or marked incorrectly.

boombox1
boombox2
native1

More In Category




halfpage1

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021