The Fenestration and Glazing Industry Alliance (FGIA) updated a specification establishing minimum performance requirements for self-adhering flashing surrounding common exterior fenestration products.
AAMA 711-20, Specification for Self-Adhering Flashing Used for Installation of Exterior Wall Fenestration Products, was created in 2007. This is the document’s second update. It was last updated in 2013.
“Self-adhered flashing products are broadly used at the window/wall interface to provide a durable moisture seal and enhance the long-term performance of the installation,” said Jim Katsaros (DuPont Performance Building Solutions), chair of the FGIA Flashing Committee, in a news release. “This document specifies essential material properties, such as adhesive bond strength to various building substrates, sealability through fastener penetrations, and weathering tests for UV and thermal exposure to help ensure the long-term performance of these products.”
The new AAMA 711 standard provides significant updates to select test methods, particularly regarding sealability through fasteners and new guidelines for minimum product width. AAMA 711 is referenced in both the IRC and IBC for the use of self-adhered flashing products around windows and doors.
Related Stories
Codes and Standards | Jul 24, 2017
Non-union labor gaining ground in New York City
President of contractors’ group says competitive pricing is spurring more open shops.
Codes and Standards | Jul 20, 2017
New tallest tower west of the Mississippi built to stringent seismic standards
L.A.’s new 1,100-foot skyscraper dominates city’s skyline.
Codes and Standards | Jul 20, 2017
Chicago rises to the top of U.S. cities in percentage of LEED or Energy Star office buildings
Certified office buildings reach 66% in windy city.
Codes and Standards | Jul 19, 2017
Economic impacts of climate change will jump over next two decades
Average annual cost to buildings and infrastructure from eastern storms to rise by $7.3 billion.
Codes and Standards | Jul 18, 2017
Energy modeling yields accuracy within 4%, says new study
Results of the study support the usefulness of the practice.
Codes and Standards | Jul 13, 2017
Net Zero Energy rebranded as ‘Zero Energy’
ILF aims to make new certification the sole standard for highest performing buildings.
Codes and Standards | Jul 13, 2017
New York City creates $10 million fund to help women- and minority-owned firms win construction contracts
The money is earmarked for up to $500,000 surety bonds per contract.
Codes and Standards | Jul 12, 2017
New International Building Code allows weather-resistive barriers above 40 feet
Danger of propagating flames now deemed negligible.
Codes and Standards | Jul 10, 2017
New mass plywood panel project moves ahead with federal grant
New material is substitute for concrete and steel in multi-story projects.
Codes and Standards | Jul 6, 2017
Trump ups ante on apprenticeships, gives private sector more room to design them
Initiative aimed at alleviating construction industry worker shortage.