NFPA life safety engineer Ron Coté settles the debate over second egress doors and exit signs.


By Peter Fabris, Contributing Editor | June 18, 2015
Two myths regarding NFPA 101 Life Safety Code debunked

Image: Pixabay

In Compliance column in the May/June issue of NFPA Journal, Ron Coté, Principal Life Safety Engineer at the National Fire Protection Agency, debunks two myths regarding NFPA 101, Life Safety Code.

The first myth is that all assembly occupancy rooms with an occupancy load more than 50 must have a second egress door. This is not true, although many do have second exit access doors “in order not to violate the common path of travel limitation,” Coté writes.

For most room locations and arrangements, a second exit access door from the room can be positioned to provide occupants with a second travel path. The presence of the second exit access door can reduce what would otherwise be an excessive common path of travel to one that is within the permitted distance.

Coté also debunks the myth that exit signs are required at exits only. The signs are actually required in three locations: at exits, in the exit access, and in exit access corridors of new construction. They are required in the exit access when the exit or way to reach the exit is not readily apparent, as might be the case where additional turns in the egress path are needed to reach an exit.

They may also be needed when in exit access corridors of new construction no point is in excess of the particular sign’s rated viewing distance or the 100-foot (30-meter) default value, whichever is less, from the nearest sign.

Related Stories

Codes and Standards | Nov 12, 2021

GSA will likely shrink federal office space post-COVID

Agency also needs to address maintenance backlog.

Codes and Standards | Nov 10, 2021

Los Angeles launches fast-track office tenant improvements program

Red tape to be cut to make interiors healthier and safer.

Codes and Standards | Nov 9, 2021

Florida state building professionals call for mandatory high-rise building inspections

Group recommendation comes in wake of Surfside condo collapse.

Codes and Standards | Nov 8, 2021

Dept. of Energy to fund 10 pilot smart building projects

Connected communities will accelerate renewable energy adoption and grid resilience.

Codes and Standards | Nov 3, 2021

Fact sheets offer strategies to improve indoor air quality in schools

Center for Green Schools at USGBC document for people without a technical background.

Codes and Standards | Nov 2, 2021

Rapid acceleration of affordable housing development expected over next five years

Federal government programs will spur construction.

Codes and Standards | Nov 1, 2021

New bird-friendly technical design guide released

National Glass Assn. document offers design and installation best practices for glazing.

Codes and Standards | Nov 1, 2021

World’s first chief heat officer tackles how to protect Miamians from extreme heat

Focus on chronic exposure for outdoor workers and for those that can’t afford AC.

Codes and Standards | Oct 28, 2021

Design competition launched to show role of mass timber in decarbonization

Forest Service and Softwood Lumber Board will award $2 million in grants to winning teams.

Codes and Standards | Oct 27, 2021

Texas reforms series of contractor laws

Measures seen as making it easier to do business in the state.

boombox1
boombox2
native1

More In Category




halfpage1

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021