The Metal Construction Association (MCA) has published a new white paper, “Fire Safety of Insulated Metal Wall Panels.”
The document contains detailed information on the efficacy of insulated metal panels (IMPs) for insulation and fire safety requirements in the U.S. and other countries. IMPs are lightweight composite exterior wall and roof panels with two layers of coated thin sheet metal (typically steel or aluminum) wrapped around a rigid foam core to form a stiff composite.
They are tested for fire, structural, thermal transmittance/resistance, foam core properties, water leakage, and air pressure differential. “In some cases, each component of a product can get good fire test results while the entire assembly burns vigorously, and vice versa,” according to a MCA news release. “Therefore, U.S. codes typically require composite assemblies to be fire tested both as a complete assembly and as separate components, particularly foam plastic insulation materials.”
"It's a misconception that non-combustible materials are always preferable to foam plastic materials in exterior claddings,” said Marcelo Hirschler of GBH International, a company specializing in fire test instruments and consulting services, in the release. “IMPs can be used safely in exterior claddings and should continue to be a significant part of building construction.”
Related Stories
Codes and Standards | Sep 16, 2016
Calm weather tidal flooding impacting several communities on East and Gulf Coasts
Local officials face the prospect of costly mitigation projects.
Codes and Standards | Sep 15, 2016
OSHA appoints new director for its construction directorate
The forty-year industry veteran has been a GC and business owner.
Energy | Sep 13, 2016
Oberlin College to hold conference on post-fossil fuel economy
The gathering will address climate change and new sources of energy.
Industry Research | Sep 12, 2016
Evidence linking classroom design to improved learning mounts
A study finds the impact can be as much as 25% per year.
Legislation | Sep 8, 2016
Half of U.S. states now allow design-build on public projects
Missouri is the latest to enact design-build legislation.
Codes and Standards | Sep 8, 2016
Vapor intrusion risk addressed in new ASTM guide update
The updates address industry confusion over how to handle the issue.
BIM and Information Technology | Sep 7, 2016
Energy Star Portfolio Manager tool updated to factor in waste management
The costs and benefits of managing 29 types of waste are now included.
Wood | Sep 6, 2016
Atlanta suburb prohibits wood-framed construction for high rises
The new building code prevents any structure with more than three stories from being built from a CLT frame.
Codes and Standards | Sep 1, 2016
Overuse of air conditioning hurts office productivity
A study found temperatures in the low 70s reduce worker performance.
Regulations | Aug 31, 2016
FEMA wants to toughen flood regulation on projects using federal funds
The proposal ‘would essentially rewrite the current 100-year flood standard.’