flexiblefullpage
billboard
interstitial1
catfish1
Currently Reading

New rule mandates annual parapet inspections for New York City buildings

Codes and Standards

New rule mandates annual parapet inspections for New York City buildings

Beginning January 1, 2024, New York City building owners must undertake a yearly inspection of parapet walls, then remedy any hazardous conditions.


By Hoffmann Architects | September 13, 2023
New rule mandates annual parapet inspections for New York City buildings Hoffmann Architects
Photo: Hoffmann Architects

In November 2021, New York City enacted Local Law 126 of 2021, which is well-known in the building industry for establishing new requirements for periodic parking garage inspections. At the same time, the legislation added a section to the NYC Administrative Code mandating periodic observation of building parapets.

To allow owners time to prepare, the City set the start date for the new parapet observations for January 1, 2024.

What is required?

All buildings in New York City with parapets facing a street, sidewalk, or other public right-of-way must undergo a professional parapet observation every year.

Unlike the Facade Inspection Safety Program (FISP), which excludes buildings under six stories, the parapet rule applies to all buildings, regardless of height, with the exception of detached single- or two-family homes. While FISP inspections are conducted on a five-year cycle, and parking garage inspections are required at least every six years, the newly mandated parapet observation must be done annually.

The good news: owners do not need to file the observation report with the Department of Buildings (DOB). Whereas facade and garage inspection reports follow prescriptive formats and must be electronically submitted, parapet reports need only be kept on file by the building owner. Archives of at least six years of parapet reports must be made available should the DOB request them.

What happens if there is a hazardous condition?

Immediately upon observing an unsafe condition, the professional performing the observation is required to notify the DOB. The building owner must promptly install public protection, such as sidewalk sheds, fences, and/or safety netting, which must remain in place until the problem is remedied. Unsafe conditions must be corrected within 90 days.

What is included in the observation report?

In contrast to the FISP and parking garage laws, the new parapet rule is not prescriptive as to report sections and format. However, the report does need to include:

  • Basic building information, including address and owner contact details;
  • Name and contact details for the professional performing the observation;
  • Date of the observation;
  • Location plan and construction information for the parapets, including material, height, and thickness;
  • Description of general conditions;
  • Unsafe conditions and actions taken to remedy them;
  • Repairs since the previous report; and
  • Dated photos documenting conditions.

Rather than filing the report with the DOB, the owner retains parapet observation reports for at least six years and must be prepared to furnish them to the DOB upon request.

What steps should owners take now?

With the requirements set to begin on the first of the year, owners have just a few months to plan. If a mandated FISP inspection is scheduled for 2024, adding a separate parapet observation report to that program may be a cost-effective strategy. Similarly, parapet observation can be incorporated into other planned exterior work, such as roof rehabilitation or facade cleaning.

A design professional can offer guidance on the simplest and most budget-conscious way to meet the new annual parapet requirements as part of existing maintenance and repair programs.

Resources

RCNY §103-15: Periodic Observation of Building Parapets

Local Law 126 of 2021 – see §28-301.1.1, p. 168

“Design Guide for Parapets: Safety, Continuity, and the Building Code,” Hoffmann Architects + Engineers JOURNAL

Hoffmann Architects + Engineers specializes in the rehabilitation of building exteriors.

Our design professionals have worked with hundreds of New York City building owners to meet inspection and repair requirements since the first facade law in 1980. We provide up-to-date guidance to help owners comply with the code and safely maintain their properties. Reach us at 212-789-9915 or hoffarch.com/contact.

Related Stories

| Nov 14, 2014

California aims for 20% reduction in water consumption by 2020

California’s comprehensive new water use plan makes conservation a priority, reinforcing a 2009 plan to reduce statewide per capita water consumption by 20% by 2020.

| Nov 6, 2014

Demountable structural steel could up the ante on sustainability

Demountable structural steel assemblies would be a greener way to make use of steel in the construction industry than recycling.

K-12 Schools | Nov 6, 2014

New Sandy Hook school features could influence security standards

The design of the new Sandy Hook Elementary School on the site of the 2012 Newtown, Conn., school shooting features enhanced security measures—some subtle and others more prominent.

| Nov 6, 2014

OSHA seeking input on electrical standards

The Occupational Safety and Health Administration (OSHA) is reviewing electrical standards for the construction industry to make sure proper safeguards are in place as electrical wiring is being installed and maintained.

Smart Buildings | Oct 30, 2014

Energy Department pledges $9 million for energy efficiency improvements on commercial buildings

The U.S. Dept. of Energy will spend $9 million to encourage investments in energy-saving technologies that can be tested and deployed in offices, shops, restaurants, hospitals, hotels and other types of commercial buildings.

| Oct 30, 2014

Steel Framing Industry Association’s certification program aims to ensure connector quality

The Steel Framing Industry Association has launched a certification program to ensure that cold-formed steel connectors meet quality guidelines, building codes, and ASTM standards.

| Oct 30, 2014

American Concrete Institute releases reorganized structural concrete code requirements

The reorganized document is organized from an engineer’s perspective. The requirements flow more intuitively and have fewer cross-references for improved logic and flow of information.

| Oct 30, 2014

USGBC pushes back LEED v4 deadline

Extending the deadline gives LEED users additional time to prepare for LEED v4, the latest version of LEED, which features increased rigor and multiple updates.

| Oct 24, 2014

Solar panels could be required on most new construction in San Francisco

A San Francisco city councilor will propose a new regulation that could soon mandate solar panels on most new construction in the city and on many existing apartment buildings.

| Oct 24, 2014

International WELL Building Institute launches green building standard

The International WELL Building Institute has launched the WELL Building Standard Version 1.0, which focuses on enhancing people’s health and well-being through the built environment.

boombox1
boombox2
native1

More In Category




halfpage1

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021