Beginning January 1, 2024, New York City building owners must undertake a yearly inspection of parapet walls, then remedy any hazardous conditions.


By Hoffmann Architects | September 13, 2023
New rule mandates annual parapet inspections for New York City buildings Hoffmann Architects
Photo: Hoffmann Architects

In November 2021, New York City enacted Local Law 126 of 2021, which is well-known in the building industry for establishing new requirements for periodic parking garage inspections. At the same time, the legislation added a section to the NYC Administrative Code mandating periodic observation of building parapets.

To allow owners time to prepare, the City set the start date for the new parapet observations for January 1, 2024.

What is required?

All buildings in New York City with parapets facing a street, sidewalk, or other public right-of-way must undergo a professional parapet observation every year.

Unlike the Facade Inspection Safety Program (FISP), which excludes buildings under six stories, the parapet rule applies to all buildings, regardless of height, with the exception of detached single- or two-family homes. While FISP inspections are conducted on a five-year cycle, and parking garage inspections are required at least every six years, the newly mandated parapet observation must be done annually.

The good news: owners do not need to file the observation report with the Department of Buildings (DOB). Whereas facade and garage inspection reports follow prescriptive formats and must be electronically submitted, parapet reports need only be kept on file by the building owner. Archives of at least six years of parapet reports must be made available should the DOB request them.

What happens if there is a hazardous condition?

Immediately upon observing an unsafe condition, the professional performing the observation is required to notify the DOB. The building owner must promptly install public protection, such as sidewalk sheds, fences, and/or safety netting, which must remain in place until the problem is remedied. Unsafe conditions must be corrected within 90 days.

What is included in the observation report?

In contrast to the FISP and parking garage laws, the new parapet rule is not prescriptive as to report sections and format. However, the report does need to include:

  • Basic building information, including address and owner contact details;
  • Name and contact details for the professional performing the observation;
  • Date of the observation;
  • Location plan and construction information for the parapets, including material, height, and thickness;
  • Description of general conditions;
  • Unsafe conditions and actions taken to remedy them;
  • Repairs since the previous report; and
  • Dated photos documenting conditions.

Rather than filing the report with the DOB, the owner retains parapet observation reports for at least six years and must be prepared to furnish them to the DOB upon request.

What steps should owners take now?

With the requirements set to begin on the first of the year, owners have just a few months to plan. If a mandated FISP inspection is scheduled for 2024, adding a separate parapet observation report to that program may be a cost-effective strategy. Similarly, parapet observation can be incorporated into other planned exterior work, such as roof rehabilitation or facade cleaning.

A design professional can offer guidance on the simplest and most budget-conscious way to meet the new annual parapet requirements as part of existing maintenance and repair programs.

Resources

RCNY §103-15: Periodic Observation of Building Parapets

Local Law 126 of 2021 – see §28-301.1.1, p. 168

“Design Guide for Parapets: Safety, Continuity, and the Building Code,” Hoffmann Architects + Engineers JOURNAL

Hoffmann Architects + Engineers specializes in the rehabilitation of building exteriors.

Our design professionals have worked with hundreds of New York City building owners to meet inspection and repair requirements since the first facade law in 1980. We provide up-to-date guidance to help owners comply with the code and safely maintain their properties. Reach us at 212-789-9915 or hoffarch.com/contact.

Related Stories

Green | Apr 16, 2015

New version of Building Energy Data Exchange Specification launched

BEDES is a dictionary that facilitates consistent exchange of building characteristics and energy use data between tools and databases in the building energy efficiency sector.

Codes and Standards | Apr 16, 2015

New York tops U.S. cities in walkability

Revitalization pushes Detroit and New Orleans up the rankings

Green | Apr 14, 2015

USGBC will recognize energy and water standards for the Living Building Challenge

This move means that projects achieving the energy and water requirements in Living Building Challenge will be considered as technically equivalent to LEED.

Codes and Standards | Apr 14, 2015

New York City preparing new codes for evacuation elevators

New York City’s Fire, Buildings, and City Planning Departments in New York are writing rules to govern occupant-evacuation elevators, reflecting a change in philosophy of how to evacuate people from skyscrapers in an emergency.

Codes and Standards | Apr 12, 2015

California imposes stringent new water standards

California is the first state to adopt standards that are more efficient than those set by EPA's WaterSense program. 

Codes and Standards | Apr 12, 2015

Virginia surpasses Florida for strictest hurricane building codes

Virginia has edged out Florida as the state with the most stringent hurricane building codes, according to the Institute for Business and Home Safety’s “2015 Rating the States” report. 

Codes and Standards | Apr 6, 2015

Industry groups petition for change order reform on federal projects

Nine design and construction associations ask for assurance that funds available for additional work.

Codes and Standards | Apr 6, 2015

DOE releases Better Buildings Workforce Guidelines

The guidelines are aimed at strengthening and streamlining commercial building workforce training and certification programs for workers in energy auditing, building commissioning, building operations, and energy management.

Green | Apr 3, 2015

Georgia may ban use of LEED on state buildings

Georgia's state legislature is considering a measure to require all state buildings to only use green building standards that permit the use of Georgia's lumber.

Codes and Standards | Mar 29, 2015

Elevator shafts a major source of heat loss in New York City

A typical New York apartment building loses thousands of dollars worth of energy every year from leaky elevator shafts that vent warm air at the top of the building and draw in cold air at the bottom, according to a new Urban Green Council report.

boombox1
boombox2
native1

More In Category




halfpage1

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021