Building owners have a responsibility to protect people who venture on their roofs, according to OSHA.
OSHA prescribed certain safety requirements that were introduced in January 2017. Among them are a raised warning line 15 feet from the roof edge, and a guardrail or cage around skylights.
OSHA has designated three work zones on low-slope roofs with unprotected edges that are four feet or more above a lower level. The extremely high danger zone (less than six feet from the roof’s edge) requires a protective feature such as a guardrail system, safety net system, personal fall protection systems (e.g., personal fall arrest, travel restraint, positioning system), or a 42-inch-high parapet.
Guardrails are typically installed six feet from the roof’s edge. If there is something near the edge like a condenser unit requiring periodic maintenance, then guardrails must be placed right up to the roof edge.
Related Stories
Codes and Standards | Oct 5, 2016
New York becomes the first city to adopt a target for energy storage
Mayor de Blasio also announces increased solar generation goals
Codes and Standards | Oct 4, 2016
New global residential floor space measurement standard unveiled
The new standards will produce better transparency and are said to benefit investors.
Codes and Standards | Sep 29, 2016
Dept. of Energy forecasts big jump in LED use, resulting energy savings
Big gains are expected in both commercial and residential markets.
Codes and Standards | Sep 28, 2016
San Francisco commercial, multifamily regulations aim to reduce traffic volume
City planners will require design features to cut miles driven.
Codes and Standards | Sep 28, 2016
Society of Landscape Architects releases guide to resilient design
The goal is to retrofit communities to better withstand extreme weather events.
Codes and Standards | Sep 26, 2016
Washington State Energy Code updates include dedicated outdoor air system requirements
The updates will change design approach to HVAC.
Codes and Standards | Sep 22, 2016
Construction firms pulling back from federal market due to new reporting rules
‘Subjective, very vague’ policies are said to create too much risk.
Codes and Standards | Sep 21, 2016
Airbnb presents legal liability for multifamily owners
How building owners can reduce risks.
Codes and Standards | Sep 21, 2016
Healthy buildings becoming a key design priority for both architects and building owners
Nationwide survey finds nearly three of four architects cite health impacts influencing design decisions
Data Centers | Sep 19, 2016
New ANSI/ASHRAE data center standard is performance-based, more flexible
The aim of the standard was to ‘not stifle innovation.’