Metals

Fire performance of Insulated Metal Panels (IMPs)

March 21, 2019
5 min read

In recent years, a handful of high-profile building fires have caused renewed scrutiny of using cladding systems with combustible content in multi-story buildings. Although these fires have not occurred in the U.S., and our building code is different than those used in the U.K. and elsewhere, the loss of life and property damage that have occurred has prompted our building officials to take a second look at how these products are evaluated for use here under the International Building Code (IBC).

It is important to understand that the IBC has different requirements regarding the use of specific materials depending on the configuration of the building as well as its end use. The requirements regarding the use of combustible cladding materials vary significantly depending on whether the structure is single or multi-story, and whether they are protected by automatic fire suppression systems. The code treats multi-story construction more stringently than single story construction because of the increased dangers to occupants of safely escaping a high-rise building during a fire event.   

Single story construction requirements for using foam plastic materials such as Insulated Metal Panels (IMPs) are found in Chapter 26 Plastic. This chapter lists various small-scale tests and approvals such as ASTM E84 and UL 723. There are also very specific instructions regarding the use of thermal barriers when using foam plastic (including IMPs). However, IMP manufacturers in the N. American marketplace have opted to conduct large-scale testing such as Factory Mutual 4880, UL 1040, UL 1715 or NFPA 286. These standards are comprised of a multitude of individual fire tests that determine various product characteristics such as flame spread, smoke development, fuel content, ignition temperatures etc. These tests are typically carried out directly by FM or UL, or in the case of NFPA 286, accredited labs that conduct NFPA testing. The results are used to create “approval reports” which verify that the requirements of Chapter 26 have been met. These large-scale testing regimens are designed to comply with section 2603.9 Special Approval. This section effectively overrides the separate thermal barrier requirements listed in 2603.4, and also establishes compliance with the requirements for using foam plastic insulation listed in section 2603.6 Roofing.     

 

     

The prevailing test standard referenced in Chapter 26 for multi-story construction using combustible components is known as NFPA 285. This standard is developed by the National Fire Protection Association, a non-profit organization devoted to “promote the science and improve the methods of fire protection and prevention”. NFPA 285 provides a “standardized fire test procedure for evaluating the suitability of exterior, non-load bearing wall assemblies and panels used as components of curtain wall assemblies that are constructed using combustible materials or that incorporate combustible components for installation on buildings where the exterior walls are required to be non-combustible” (www.nfpa.org). To summarize, the code allows the use of combustible materials in non-combustible assemblies if they can comply with this standard. Many building materials fall into this category including insulated metal panels, aluminum composite panels, rigid insulation boards (foam plastics), some air barrier sheathing products etc. Many of these products are the materials of choice for multi-story construction because of their thermal efficiency, effectiveness as environmental control layers (air/vapor/water), light weight, ease of installation, low cost and excellent aesthetics.   

This is also the standard that is currently causing the most confusion amongst architects, engineers, contractors, product manufacturers and even some building officials. Most of the confusion surrounds the requirement that the tested assembly is representative of the installed configuration. This can be quite problematic, as even slight changes in the installed configuration not affecting fire performance could be interpreted as not in compliance with tested assemblies. There are also many, many permutations in wall construction due to the multitude of rainscreen systems, air barriers, foam plastic insulation and barrier walls assemblies used in multi-story applications, and it is simply not feasible to test them all. Fortunately, fire safety engineering reports (also known as “engineering judgments”) from accredited firms can sometimes be used to substantiate compliance.    

 

 

As with most everything in the construction industry, the “devil is in the details”. The current efforts to amend NFPA 285 are designed to provide additional protection against the types of fires that have occurred recently in other parts of the globe. Specifically, there is an effort to modify the standard to make it more rigorous and to reflect common installation and design practices so that it better reflects actual performance in a fire event. In effect, by changing the test parameters to reflect worst case performance, the goal is to provide maximum protection to building occupants.     

Building codes can be difficult to understand. The good news is that responsible IMP manufacturers are here to help architects, engineers, contractors and authorities having jurisdiction (AHJs) on how to properly interpret the use of IMPs under both the IBC and the Canadian Building Codes.

About the Author

Metl-Span

Metl-Span is a dynamic industry innovator dedicated to manufacturing and marketing the highest quality insulated building panel products since 1968. We are a recognized leader in the advancement of insulated metal panel technology. With our history of visionary product design – and by consistently setting the highest standards in technological advances – architects, designers and builders trust Metl-Span panel products to perform reliably, be aesthetically-pleasing and come with a proven sustainability track record. Structural integrity, tireless testing and a determination to exceed expectations are primary to Metl-Span’s focus. At Metl-Span, form meets function in the most reliable, cost- and energy-efficient manner possible. For more information, please visit http://www.metlspan.com/.

 

 