The American Iron and Steel Institute (AISI) has published three new cold-formed steel framing research reports: 1) “RP15-3: Advancing Seismic Simulation of Cold-Formed Steel Framed Buildings,” 2) “RP17-1: Experimental Study on System Reliability of Cold-Formed Steel Roof Trusses,” and 3) “RP17-2: Monotonic and Cyclic Response of Single Shear Cold-Formed Steel-to-Steel and Sheathing-to-Steel Connections.”
“RP15-3: Advancing Seismic Simulation of Cold-Formed Steel Framed Buildings.” This report advances performance-based seismic design of cold-formed steel framed buildings by introducing computationally efficient and accurate modeling tools that predict the behavior of the building, the individual cold-formed steel components, and connections in a seismic event.
“RP17-1: Experimental Study on System Reliability of Cold-Formed Steel Roof Trusses.” This study of cold-formed steel roof trusses was part of a project funded by the National Science Foundation, “Advancing System Reliability With Application to Light-Framed Structures.” Test data are provided for examining cold-formed steel structural reliability in roof trusses as a system versus individual components.
“RP17-2: Monotonic and Cyclic Response of Single Shear Cold-Formed Steel-to-Steel and Sheathing-to-Steel Connections.” Researchers developed load-deformation response models to simulate the performance of screw fasteners in a seismic event. Since screw fasteners are the primary connectors in light steel framing, this research provides designers with more accurate performance-based data for conducting whole building seismic analysis.
Related Stories
| Apr 5, 2012
LEED 2012 will include new requirements for data centers
The U.S. Green Building Council’s updated LEED 2012 standards will require two systems to be modeled for each project in order to show power utilization effectiveness.
| Mar 30, 2012
CSI webinar: Durable & energy efficient building envelope design, April 24
This seminar will review recent changes in North America energy codes, examples of building enclosure wall assemblies being considered for code compliance, potential moisture management and durability challenges, and design tools that could be used to assess and minimize potential problems.
| Mar 30, 2012
Improved construction that followed seismic codes helped avert loss of life in Mexico temblor
A magnitude-7.4 earthquake that shook Mexico from Mexico City to Acapulco damaged hundreds of homes and sent thousands fleeing from swaying office buildings, yet no one was killed, according to early reports.
| Mar 30, 2012
Chicago may allow people to live in retail spaces
The Chicago City Council’s Zoning Committee approved a zoning change that will allow up to 50% of work space in low-intensity business districts to be used for living space.
| Mar 30, 2012
LEED growing fast in the housing rental market
Last year, developers of 23,000 U.S. multifamily housing units applied for LEED certification.
| Mar 30, 2012
Forest Stewardship Council critical of proposed LEED 2012 changes
According to the Forest Stewardship Council (FSC), the third draft of LEED 2012, if approved as written, would represent a step backward from the current Certified Wood Credit.
| Mar 22, 2012
Symposium on water efficiency: How much more water can be saved?
The Third International Emerging Technology Symposium by IAPMO and the World Plumbing Council features a session on water efficiency.
| Mar 22, 2012
Broker doesn’t have to inform contractor that insurer went broke, California court rules
A California appellate court ruled that an insurance broker did not have a duty to inform a subcontractor that a project’s insurer had gone bankrupt.