flexiblefullpage
billboard
interstitial1
catfish1
Currently Reading

AISC seeks comments on draft earthquake standard for steel buildings

Codes and Standards

AISC seeks comments on draft earthquake standard for steel buildings

Includes new limits for cross-sectional slenderness of steel columns based on latest research.


By Peter Fabris, Contributing Editor | January 17, 2022
Steel tubes and beams

Courtesy Pixabay

The American Institute of Steel Construction (AISC) recently issued a draft of AISC 341, a standard that provides guidance on designing earthquake-resistant steel buildings and it is available for public comments.

The draft standard incorporates new design limits for steel columns based on research conducted by the National Institute of Standards and Technology (NIST) and the University of California San Diego. Using a shake table, researchers identified deficiencies in the performance of a certain type of column, with many test assemblies buckling prematurely.

Based on the findings, the researchers devised new limits for the cross-sectional slenderness of steel columns. “A lot of current design provisions are based on scaled-down column tests or a very small number of full-scale tests,” said NIST structural engineer John Harris in a news release. “But the full-scale testing we conducted has allowed us to begin filling in the knowledge gap regarding the performance of these kinds of columns under extreme loading conditions.”

The draft includes new slenderness limits on columns, with structural steel webs—sized according to the new limit—that could meet drift and stability requirements at the same time. The more stringent limits on steel column webs could soften the blow of earthquakes, potentially saving newly designed buildings from unnecessary damage or partial collapse.

Related Stories

Codes and Standards | Sep 29, 2016

Dept. of Energy forecasts big jump in LED use, resulting energy savings

Big gains are expected in both commercial and residential markets.

Codes and Standards | Sep 28, 2016

San Francisco commercial, multifamily regulations aim to reduce traffic volume

City planners will require design features to cut miles driven.

Codes and Standards | Sep 28, 2016

Society of Landscape Architects releases guide to resilient design

The goal is to retrofit communities to better withstand extreme weather events.

Codes and Standards | Sep 22, 2016

Construction firms pulling back from federal market due to new reporting rules

‘Subjective, very vague’ policies  are said to create too much risk.

Codes and Standards | Sep 21, 2016

Airbnb presents legal liability for multifamily owners

How building owners can reduce risks.

Codes and Standards | Sep 21, 2016

Healthy buildings becoming a key design priority for both architects and building owners

Nationwide survey finds nearly three of four architects cite health impacts influencing design decisions

Data Centers | Sep 19, 2016

New ANSI/ASHRAE data center standard is performance-based, more flexible

The aim of the standard was to ‘not stifle innovation.’

Codes and Standards | Sep 16, 2016

Calm weather tidal flooding impacting several communities on East and Gulf Coasts

Local officials face the prospect of costly mitigation projects.

Codes and Standards | Sep 15, 2016

OSHA appoints new director for its construction directorate

The forty-year industry veteran has been a GC and business owner.

boombox1
boombox2
native1

More In Category



Resiliency

U.S. is reducing floodplain development in most areas

The perception that the U.S. has not been able to curb development in flood-prone areas is mostly inaccurate, according to new research from climate adaptation experts. A national survey of floodplain development between 2001 and 2019 found that fewer structures were built in floodplains than might be expected if cities were building at random.


halfpage1

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021