The 2016 version of the American Institute of Steel Construction (AISC) standard, Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications (ANSI/AISC 358-16) is now available for free downloading on the AISC website at www.aisc.org/aisc358.
This updated version has been expanded to cover nine connections:
• Reduced beam section moment connections
• Bolted stiffened and unstiffened extended end-plate moment connections
• Bolted flange plate moment connections
• Welded unreinforced flange-welded web moment connections
• Kaiser bolted bracket moment connections
• ConXtech ConXL moment connections
• SidePlate moment connections
• Simpson Strong-Tie Strong Frame moment connections
• Double-tee moment connections
In addition to general requirements and limitations, each prequalified connection chapter includes a step-by-step design procedure. The new standard has been approved by the AISC Connection Prequalification Review Panel (CPRP) and is ANSI-accredited.
“With the release of AISC 358-16, there are now nine prequalified beam-to-column moment connections for Special and Intermediate Moment Frames,” said Michael D. Engelhardt, chairman of the committee. “Work is already underway to prequalify additional connections and to extend the range of use for some of the existing prequalified connections, with the goal of providing designers with an ever growing range of options.”
Related Stories
| Jan 5, 2012
Some ADA accessibility rules change in 2012
Some changes to the Americans with Disabilities Act go into effect beginning March 15, 2012.
| Jan 3, 2012
New SJI Rule on Steel Joists
A new rule from the Steel Joist Institute clarifies when local reinforcement of joists is required for chord loads away from panel points. SJI members offer guidance about how and when to specify loads.
| Dec 29, 2011
OSHA enforcing new fall hazard standards
OSHA is enforcing its new fall protection standards, as evidenced by a recent crackdown in New York.
| Dec 29, 2011
NRCA offers program on new fall-protection requirements
The National Roofing Contractors Association's (NRCA's) program "Roofing Industry Fall Protection from A to Z" will be held Feb. 21 during the organization's 125th Annual Convention.
| Dec 29, 2011
Decision not to fireproof the new World Trade Center Transportation Hub criticized
Some criticized the decision, reasoning that the structure could be a terrorist target.
| Dec 29, 2011
Seismic safety in question at thousands of California public schools
California regulators responsible for enforcing earthquake safety laws have failed to certify more than 16,000 construction projects in California public schools, increasing the risk that some projects may be unsafe, according to a state audit report.
| Dec 29, 2011
GreenWizard offers cloud-based LEED credit management, assessment
The company recently began offering companies the ability to run assessments for design credits, in addition to traditional product-specific LEED credits.
| Dec 22, 2011
Federal home weatherization program has impacted 6.8 million homes
More than 6.8 million homes have been weatherized using federal, state, utility, and other funds under the American Recovery and Reinvestment Act.
| Dec 22, 2011
Group developing BIM data standards
A collaboration among Georgia Tech’s Digital Building Lab, the Precast Concrete Institute, the American Concrete Institute, and the American Institute of Steel Construction aims to develop global standards for transportation of three-dimensional digital models among fabricator, architecture, engineering, and construction groups.
| Dec 22, 2011
New green code spells out thermal requirement for roof retrofits
The 2012 International Green Construction Code (IgCC) includes a straightforward approach to minimum thermal requirements for roof and wall systems.