The American Architectural Manufacturers Association (AAMA) recently released an updated document to provide a standard water penetration test method when using dynamic pressure.
AAMA 501.1-17, the Standard Test Method for Water Penetration of Windows, Curtain walls and Doors Using Dynamic Pressure, establishes the equipment and procedures for testing. Included is a section on test equipment updated to clarify what to do for laboratory testing versus on-site testing.
“The AAMA 501.1 dynamic pressure water test has been used as a laboratory test for over 50 years, and is particularly useful when testing pressure equalized fenestration systems when severe windblown rain is a concern,” said Greg McKenna (Kawneer), officer of the AAMA Methods of Test Committee. “In more recent years, this test has been used in the field due to the added benefit that a separate vacuum chamber is not needed. This is an advantage if the building is occupied or if constructing a chamber at the building site is not a practical option.”
Additional edits to this updated standard include the addition of two figures showing images of acceptable water leakage, plus a definition for what unacceptable water penetration means.
Related Stories
| Feb 17, 2012
Comment period opens March 1 for LEED 2012 update
USGBC says that LEED's strength comes from its continuous evolution.
| Feb 17, 2012
OSHA training videos on proper respirator use available online
17 short videos to help workers learn about the proper use of respirators on the job.
| Feb 17, 2012
Union/employer collaboration on the rise aimed at exceeding OSHA safety standards
Unions have learned to help employers win contracts with bids made competitive through good safety practices.
| Feb 16, 2012
Gain greater agility and profitability with ArchiCAD BIM software
White paper was written with the sole purpose of providing accurate, reliable information about critical issues related to BIM and what ArchiCAD with advanced technology such as the GRAPHISOFT BIM Server provide as an answer to address these issues.
| Feb 9, 2012
Initiative to sell off under-used federal property gaining momentum
The bill is similar to a White House planto cut $8 billion worth of building costs by the end of the 2012 fiscal year, and to establish a panel to identify other sites worth selling or donating to nonprofits or state and local governments.
| Feb 9, 2012
Computer tool helps engineers design roof cladding using Canada's building code
Easier to design roof cladding that can withstand winds in a given area.
| Feb 9, 2012
Webinar focuses on lessons learned from LEED-certified industrial project
This case study will focus on strategies used to save the client money, achieve certification, and effectively market success once the project was complete.
| Feb 9, 2012
Rapid growth of zero energy buildings expected
Much of that growth will be in the European Union, where near-zero energy buildings are mandated by 2019 for public buildings, and by 2021 for all construction.
| Feb 9, 2012
Stiffer OSHA fines put strain on Kansas contractors
A fine for a violation that once cost between $750 and $1,200 now runs $7,000 or more per incident, according to a state industry association official.