The American Architectural Manufacturers Association (AAMA) recently released an updated document to provide a standard water penetration test method when using dynamic pressure.
AAMA 501.1-17, the Standard Test Method for Water Penetration of Windows, Curtain walls and Doors Using Dynamic Pressure, establishes the equipment and procedures for testing. Included is a section on test equipment updated to clarify what to do for laboratory testing versus on-site testing.
“The AAMA 501.1 dynamic pressure water test has been used as a laboratory test for over 50 years, and is particularly useful when testing pressure equalized fenestration systems when severe windblown rain is a concern,” said Greg McKenna (Kawneer), officer of the AAMA Methods of Test Committee. “In more recent years, this test has been used in the field due to the added benefit that a separate vacuum chamber is not needed. This is an advantage if the building is occupied or if constructing a chamber at the building site is not a practical option.”
Additional edits to this updated standard include the addition of two figures showing images of acceptable water leakage, plus a definition for what unacceptable water penetration means.
Related Stories
| Apr 13, 2012
CSI webinar: Green Construction Codes Are Here -- Now What?
This seminar will trace the origins of green codes, how they compare and differ from the rating systems that have been used, and examine some of their main features.
| Apr 5, 2012
Retailers, banks among most affected by new ADA rules
On March 15, the most significant changes to the Americans with Disabilities Act (ADA) since it became law in 1991 went into effect.
| Apr 5, 2012
Florida ranks first in hurricane building codes and enforcement
Florida ranks highest among 18 hurricane-region states for building codes and their enforcement, according to the Insurance Institute for Business & Home Safety.
| Apr 5, 2012
New IgCC green building code is a ‘game changer,’ AIA official says
An AIA official calls the new International Green Construction Code (IgCC) a “game changer” for sustainable construction.
| Apr 5, 2012
Model energy codes add thousands to cost of new apartment construction, study says
New energy codes could add thousands of dollars to the construction costs of each individual apartment residence in a multifamily building, according to new research commissioned by the National Multi-Housing Council and the National Apartment Association.
| Apr 5, 2012
LEED 2012 will include new requirements for data centers
The U.S. Green Building Council’s updated LEED 2012 standards will require two systems to be modeled for each project in order to show power utilization effectiveness.
| Mar 30, 2012
CSI webinar: Durable & energy efficient building envelope design, April 24
This seminar will review recent changes in North America energy codes, examples of building enclosure wall assemblies being considered for code compliance, potential moisture management and durability challenges, and design tools that could be used to assess and minimize potential problems.
| Mar 30, 2012
Improved construction that followed seismic codes helped avert loss of life in Mexico temblor
A magnitude-7.4 earthquake that shook Mexico from Mexico City to Acapulco damaged hundreds of homes and sent thousands fleeing from swaying office buildings, yet no one was killed, according to early reports.