The American Architectural Manufacturers Association (AAMA) recently released an updated document to provide a standard water penetration test method when using dynamic pressure.
AAMA 501.1-17, the Standard Test Method for Water Penetration of Windows, Curtain walls and Doors Using Dynamic Pressure, establishes the equipment and procedures for testing. Included is a section on test equipment updated to clarify what to do for laboratory testing versus on-site testing.
“The AAMA 501.1 dynamic pressure water test has been used as a laboratory test for over 50 years, and is particularly useful when testing pressure equalized fenestration systems when severe windblown rain is a concern,” said Greg McKenna (Kawneer), officer of the AAMA Methods of Test Committee. “In more recent years, this test has been used in the field due to the added benefit that a separate vacuum chamber is not needed. This is an advantage if the building is occupied or if constructing a chamber at the building site is not a practical option.”
Additional edits to this updated standard include the addition of two figures showing images of acceptable water leakage, plus a definition for what unacceptable water penetration means.
Related Stories
Codes and Standards | Nov 15, 2018
New versions of DOE’s EnergyPlus engine and the OpenStudio software development kit released
New offerings resolve over 70 bugs and offer new features.
Codes and Standards | Nov 14, 2018
Obsolete safety standards may have been used in cleanup of former naval shipyard
San Francisco redevelopment site work may have been racked by fraud.
Codes and Standards | Nov 13, 2018
New York City’s new construction safety requirements are delayed
Some contractors say they weren’t ready for ‘massive initiative’.
Codes and Standards | Nov 9, 2018
Cities have multiple strategies to reduce parking requirements
Each community has to find its own mix of solutions.
Codes and Standards | Nov 8, 2018
Denver replaces green roof mandate with cool roof option
Less costly light-colored roofs can cut project costs by about 1.5%.
Codes and Standards | Nov 7, 2018
New report addresses sound transmission of wood-framed assemblies
AWC document provides empirical sound transmission model.
Codes and Standards | Nov 6, 2018
AIA releases 13 new and updated contract documents
Includes new Contractor-Subcontractor Master Agreement.
Codes and Standards | Nov 2, 2018
New Milwaukee Bucks home called world’s first bird-friendly sports arena
Design will make bird collisions less likely.
Codes and Standards | Nov 1, 2018
Several barriers holding back widespread construction of zero energy buildings
Code improvements and voluntary programs could add momentum.
Codes and Standards | Oct 31, 2018
Boston’s new flood protection plan centers on new parks
Initiative would add 67 acres of public open space.